Virginia Bids > Bid Detail

N059--Motorola Radio Upgrades

Agency:
Level of Government: Federal
Category:
  • N - Installation of Equipment
Opps ID: NBD00159183392606224
Posted Date: Mar 8, 2024
Due Date: Mar 18, 2024
Source: https://sam.gov/opp/f505b455d6...
Follow
N059--Motorola Radio Upgrades
Active
Contract Opportunity
Notice ID
36C25024Q0398
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • All Dates/Times are: (UTC-05:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Mar 08, 2024 05:59 am EST
  • Original Response Date: Mar 18, 2024 10:00 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: May 17, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: N059 - INSTALLATION OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:
    ANN ARBOR VA MEDICAL CENTER 2215 FULLER ROAD CONTACTING THE FACILITY IS PROHIBITED ,
    USA
Description
This is a Sources Sought Notice for Motorola Radio Coverage Equipment and Installation services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.

The services required are provided and are subject to changes. A draft SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.

Please respond if you have the ability and actual intention to complete this requirement. Include the following information in your response:

DUNS NUMBER
SAM UEI NUMBER
Capabilities Statement
Confirmation of actual intent to submit an offer should an RFQ be posted in future
Company name and address
Point of contact information (name, phone, email)
Socioeconomic size status (example: large, small, WOSB, SDVOSB, etc.)

This Sources Sought Notice is intended to locate any business capable of performance.

The anticipated NAICS Code for this requirement is 238210.

This is not a Request for Quotation and quotes shall not be reviewed at this time.

The Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.

This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.

Responses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov by Monday, March 18, 2024, by 10:00 AM Eastern Time (ET). Responses MUST include 36C25024Q0398 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.

DRAFT STATEMENT OF WORK

GENERAL
Ann Arbor VA Medical Center (AAVA), located at 2215 Fuller Road, Ann Arbor, Michigan 48105, requires equipment and installation services (as identified in the equipment list below) on existing the Motorola radio communication system, to rectify poor coverage throughout the facility.

SCOPE OF WORK
Contractor shall provide all materials, parts, labor, personnel, transportation and tools to install the equipment listed below. Any items being provided by VA are identified. Contractor materials to be provided include, but are not limited to, rigging equipment, lifts, carts/dollies, personal protective equipment (PPE), personal lockout/ tagout locks and any other items required for full contract performance. Equipment must be same or equivalent to the following specifications.

EQUIPMENT AND INSTALLATION LIST
Type
MFR
Model
Description
Inventory#
Qty
Cable
AirCell-Trilogy
AP6012J50-RD
AirCell® Red Plenum, 1/2 , 50 Ohm, Corrugated (6 GHz), Jacketed CMP, Conforms to NFPA-262, UL-444
DSAP6012J50RD
4500.00 feet
Connector
AirCell-Trilogy
NFP01250-PIM
N Type, Female Connector for 1/2 AirCell® Plenum & In-Conduit Cables, 50 Ohm
DSNFP01250PIM
29
Connector
AirCell-Trilogy
NMP01250-PIM
N Type, Male Connector for 1/2 AirCell® Plenum & In-Conduit Cables, 50 Ohm
DSNMP01250PIM
3
Cable
Comba
JS-NMNM3F-R141
3ft 0.141 jumper cable. N Male to N Male. Plenum rated with red jacket.
DSJSNMNM3FR141
29
Cable
Comba
JS-NMNM6F-R141
6ft 0.141 jumper cable. N Male to N Male. Plenum rated with red jacket.
DSJSNMNM6FR141
8
Antenna
MP Antenna
08-ANT-0908-138-151
Omni DAS Antenna - Multi-Polarized - 12MHz Bandwidth, MP-Custom, White, N-Female w/2' jumper, 138-151 MHz
DS08ANT0908138151
13
Splitter
Westell
CV05-522-614
138-960 MHz , POWER TAPPER, 3dB, 200W, N-Type
DSCV05522614
2
Splitter
Westell
CV05-527-614
138-960 MHz , POWER TAPPER, 10dB, 200W, N-Type
DSCV05527614
3
Splitter
Westell
CV05-528-614
138-960 MHz , POWER TAPPER, 13dB, 200W, N-Type
DSCV05528614
2
Splitter
Westell
CV05-529-614
138-960 MHz , POWER TAPPER, 15dB, 200W, N-Type
DSCV05529614
1
Splitter
Westell
CV05-530-614
138-960 MHz , POWER TAPPER, 20dB, 200W, N-Type
DSCV05530614
4
Splitter
Westell
CV05-531-614
138-960 MHz , POWER TAPPER, 30dB, 200W, N-Type
DSCV05531614
1

WARRANTY
All materials, parts and installation work will have a minimum one-year warranty period from the date of installation.

TASK REQUIREMENTS
Complete pre-job safety checklist.
Perform Lockout/Tagout procedure. Coordinate with VA staff.
Install additional repeaters to existing system as needed in basement.
Install all associated equipment and material for repeaters.
Perform testing of all equipment installed.
Commission system once completed.
Clean up the work area when complete and haul away all debris.
Work to be completed in approximately 2 weeks.

VA WILL PROVIDE
Lockout/Tagout of effected equipment.
Guidance of location of eyewash/safety showers, alarm pull stations, building exits, emergency procedures.
Guidance on vehicle and equipment staging.
Verify work has been completed by VA standards.

CONFORMANCE STANDARDS
Contractor shall conform to OSHA standards and VA rules and regulations. Proper PPE and safety training are required.

SAFETY REQUIREMENTS
Contractor shall follow all safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer s Representative (COR) or designated alternate/additional point of contact shall notify Contractor of any safety issues and actions necessary to correct them. Such notice, when served on the Contractor or his representative at the work site shall be deemed sufficient for the corrective actions to be taken. If Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.

VA ONSITE REPORTING REQUIREMENTS
Contractor shall be report to the Electrical Shop Supervisor in Building 28 and sign. Before or after normal work hours, Contractor shall report to the Utility Systems Repairer Operator on duty. This check in is mandatory.

DAYS AND HOURS OF OPERATION
Hours of work are Monday through Friday, 7:00 am to 3:30 pm, excluding federal holidays, or any day deemed a federal holiday by the President of the United States. Federal holidays are listed at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/
Attachments/Links
Contact Information
Contracting Office Address
  • VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
  • DAYTON , OH 45428
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Mar 08, 2024 05:59 am ESTSources Sought (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >