J065--Biosafety Cabinet and Hood Certification Services

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159747762133185
Posted Date: Oct 31, 2022
Due Date: Nov 4, 2022
Solicitation No: 36C24E23Q0004
Source: https://sam.gov/opp/4a79d60d0c...
Follow
J065--Biosafety Cabinet and Hood Certification Services
Active
Contract Opportunity
Notice ID
36C24E23Q0004
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
RPO EAST (36C24E)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Updated Published Date: Oct 30, 2022 12:37 pm EDT
  • Original Published Date: Oct 21, 2022 12:24 pm EDT
  • Updated Date Offers Due: Nov 04, 2022 11:59 am EDT
  • Original Date Offers Due: Oct 28, 2022 11:59 am EDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Jan 03, 2023
  • Original Inactive Date: Dec 27, 2022
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 811210 - Electronic and Precision Equipment Repair and Maintenance
  • Place of Performance:
    VA Salt Lake City Healthcare System ,
Description
Amendment to Solicitation 36C24E23Q0004
This Solicitation is amended with answers to questions posed during original run of Combined Solicitation and Synopsis:
1. Could you please provide an equipment list so that we can identify the items to be tested?

2. Will the project manager of the service requires CETA and NSF 49 accreditation? The CETA accreditation is quite specific to Pharmacies in general and NSF 49 covers the field testing of Class II biological safety cabinets.
We will not need CETA, but the certification needs to be completed within the standards of NSF 49. We are the Research side of the VA; therefore, no pharmacy or related clean room.
There is an Animal Facility. Any equipment with a location of building 7, would be in the Animal Facility. A complete list of equipment will not be furnished for the solicitation.
3. How many facility escort officers will be provided while the contractor is onsite? Will we be able to work in multiple locations/buildings simultaneously?
One for certain, we may at time be able to provide a second. They will be able to work in multiple locations.

4. Are all units on the same test and certification schedule? If so, when is the certification to be completed by (what month)?
All units will be on the same schedule. It will be annually, from the date of the first certification.
5. Will all units be available to be tested and certified in one visit or will the test and certification require multiple visits?
We will strive for one visit; however, if any hoods fail, it will require a secondary, follow up visit after repairs are made.
6. Statement of Work states "Vendor needs to have capability to perform minor repairs or further maintenance if a cabinet/hood does not meet certification standards upon initial testing or describe the problem so a qualified technician can perform the repairs," generally we provide an quote if a BSC or Fume hood fails the certification. The quote would consist of parts, labor, and re-certification. Is this going to be the case and will there be a Line Item for the repairs/recertification?
The vendor provides one year warranty; therefore, responsible for addressing any issue on the first year. Yes, please include Not to Exceed estimate in the quote.

Additional comments the SME thought would be relevant:
1. All Fume Hood have Air Flow Velocity Meters install. Some are OEM to the hood, others are after market installation. All meters will need to be verified and calibrated as needed, to accurately show the operation of the Fume Hood.

2. The contractor will not be required to go up on the roofs of any buildings. Any inoperably blower motor/fan, located on the roof, relating to the Fume Hoods, i.e., burnt out motor, broken belts, those repairs will be performed by VA maintenance staff. Contractor, however, would be required to verify the proper operation of the hood after repairs have been made.

Submissions are still subject to all terms within original solicitation. Receipt of submissions is extended to NLT 11:59 EST, Friday, October 4, 2022, to ensure properly estimated quotes.
Attachments/Links
Attachments
Document File Size Access Updated Date
36C24E23Q0004_3.docx (opens in new window)
1005 KB
Public
Oct 30, 2022
36C24E23Q0004_2.docx (opens in new window)
26 KB
Public
Oct 21, 2022
file uploads

Contact Information
Contracting Office Address
  • 323 NORTH SHORE DRIVE SUITE 500
  • PITTSBURGH , PA 15212
  • USA
Primary Point of Contact
Secondary Point of Contact


History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >